sub-metering fluxgate current sensor DXE2000-M6/61
$1≥100Piece/Pieces
Payment Type: | T/T |
Incoterm: | FOB,CFR,CIF,EXW,FCA |
Min. Order: | 100 Piece/Pieces |
Transportation: | Ocean,Land,Air,Express |
Port: | SHANGHAI,NINGBO,GUANGZHOU |
$1≥100Piece/Pieces
Payment Type: | T/T |
Incoterm: | FOB,CFR,CIF,EXW,FCA |
Min. Order: | 100 Piece/Pieces |
Transportation: | Ocean,Land,Air,Express |
Port: | SHANGHAI,NINGBO,GUANGZHOU |
Model No.: DXE2000-M6/61
Brand: DEXIE, OEM Service is available
Place Of Origin: China
Accuracy: 0.001%
Selling Units | : | Piece/Pieces |
Package Type | : | Cartons / Pallet |
The file is encrypted. Please fill in the following information to continue accessing it
Flux Gate Current Sensor DXE2000-M6/61 IP N = 2000 A
The DXE2000-M6/61 is a advanced flux gate current sensor that use high technology to bring the best combination of performance and reliability. It is rated for a primary current measurement range of ±2000A dc. It is calibrated and temperature compensated for improved accuracy using multi-point temperature characterization.
DIFFERENTIATION
● Accuracy: Multi-point temperature characterization and calibration for improved accuracy over temperature range.
● Magnetic immunity: Flux gate configuration and optimized magnetic circuit allow for excellent performance in diverse magnetic environments.
● Flexible: Customizable on-board firmware to meet specific application requirements.
Features
● Excellent accuracy
● Very good linearity
● Low temperature drift
● Wide frequency bandwidth
● Optimized response time
Application Domain
● Metrological verification and calibration
● Laboratory current measurement
● Instrumentation (e.g. power analyzer)
● Medical equipment, such as magnetic resonance imaging(MRI)
● Battery pack detection
● Power control
Electrical data
Parameter | specifications | Condition | ||
Minimum value | Standard value | Maximum value | ||
Rated input current IPN= | ±2000 Adc | / | ||
Measure range IPM= |
| ±2200 Adc | 1Min/Hour | |
Power supply voltage VC | ±14 Vdc | ±16 Vdc | Full range | |
Current consumption IC | ±60 mA | ±860 mA | ±940 mA | IPM range |
Current change KN | 2500:1 | Input : Output | ||
Rated output current ISN | 800 mA | Rated input current | ||
Measuring resistance RM | 3Ω | 4Ω |
Accuracy- Dynamic Parameter
Project | Symbol | Test conditions | Numerical value | Unit | ||
minimum | standard | maximum | ||||
Accuracy | Xe | @0%~25%IPN | -- | -- | 0.005 | A |
@25%IPN~IPM | -- | -- | 0.001 | %RD | ||
Ratio error | XGe | @0%~25%IPN | -- | -- | 0.005 | A |
@25%IPN~IPM | -- | -- | 0.001 | %RD | ||
angle error | XPe |
| -- | -- | 0.01 | crad |
Linearity | εL | -- | -- | -- | 5 | ppm |
Temperature drift coefficient | TCI | -- | -- | -- | 0.2 | ppm/K |
Time drift coefficient | TT | -- | -- | -- | 0.5 | ppm/month |
Power supply anti-interference | TV | -- | -- | -- | 1 | ppm/V |
Zero offset current | Io | 25±10℃ | -- | -- | ±0.002 | mA |
Zero offset current | IoT | Within the full operating temperature range | -- | -- | ±0.005 | mA |
Ripple current | In | DC-10Hz | -- | -- | 1 | ppm |
Dynamic response time | Tr | di/dt=100A/us | -- | -- | 1 | us |
rise to 90% IPN | ||||||
Current following speed | di/dt | -- | 100 | -- | -- | A/us |
Bandwidth(- 3 dB) | F | -- | 0 | -- | 100 | kHz |
General characteristics
Project | Symbol | Test conditions | Numerical value | Unit | ||
minimum | standard | maximum | ||||
Operating temperature range | TA | -- | -40 | -- | 85 | ℃ |
Storage Temperature Range | TS | -- | -45 | -- | 85 | ℃ |
Weight | m |
| 3000g±500g | g |
Safety characteristics
Project | Symbol | Test conditions | Numerical value | Unit | |||
minimum | standard | maximum | |||||
Withstand voltage | Between primary and secondary edges | Vd | 50Hz,1min |
| 2.5 |
| KV |
Transient isolation withstand voltage | Between primary and secondary edges | Vw | 50us |
| 5 |
| KV |
Mechanical characteristics
● General tolerance: ± 1mm
● Connector: DB9
NOTE
● When the direction of the input current IP is consistent with the direction indicated by the arrow in the outline drawing, the output current IS is in the forward direction.
● Please try to locate the primary conductor at the center of the probe aperture as much as possible.
● The through-hole is made of metal material, so the through-hole wire cannot be an exposed cable. The through-hole wire must be insulated.
● This module is a standard sensor, please contact us for special applications.
● We reserve the right to modify this sensor manual without prior notice.
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.