Home> Products> Current Sensor> Battery aging cabinet fluxgate current sensor DXE-CAB500
Battery aging cabinet fluxgate current sensor DXE-CAB500
Battery aging cabinet fluxgate current sensor DXE-CAB500
Battery aging cabinet fluxgate current sensor DXE-CAB500

Battery aging cabinet fluxgate current sensor DXE-CAB500

$1-1 /Piece/Pieces

Payment Type:T/T
Incoterm:FOB,CFR,CIF,EXW,FCA,Express Delivery
Min. Order:100 Piece/Pieces
Transportation:Ocean,Land,Air,Express
Port:SHANGHAI,NINGBO,GUANGZHOU
Product Attributes

Model No.DXE-CAB500

BrandDEXIE, or OEM service is available

Place Of OriginChina

Accuracy±0.1%

Packaging & Delivery
Selling Units : Piece/Pieces

The file is encrypted. Please fill in the following information to continue accessing it

Product Description

Current transducer DXE500CAB               IP N = 500 A


The zero bias current is less than 10mA due to the use of a flux gate principle, no hysteresis effect, still present after 1000A high current impact capable of maintaining low bias and high accuracy characteristics.

Especially suitable for high accuracy power battery level monitoring management system applications.

All functions and environmental usage conditions of the sensor meet the requirements of automotive grade level.


Features

● Good linearity-Linearity error<0.1%

● Wide voltage supply-Power supply voltage+11V -+30V

● Power protection function-Overvoltage automatic protection

● Good accuracy-Accuracy: 0.2%-Temperature drift<50ppm

● Digital communication-High speed CAN2.0 interface

● Sensor operating temperature range: -40 ℃ - +105 ℃


Application Domain

● Electric vehicle Battery management system (BMS)

● Electric Vehicle Battery System Distribution Box (BDU)

● High voltage distribution box (PDU) for electric vehicles

● Energy Management of Industrial Lithium Batteries

● Equipment Ground Tank Backup Power


Electrical data

Parameter

specifications

Condition

Minimum value

Standard value

Maximum value

Rated input IPN=

-500A

 

500A

/

Measure range IPM=

-600A

 

600A

 

Power supply current UC

11V

12V/24V

30V

 

Working current @Ip=0A IC

 

30mA

 

Uc=12V,T=25

Working current @I PM IC

 

160mA

 

Uc=12V,T=25

Linearity Error L

-0.001

 

0.001

±30

Zero deviation @ Ip=0A Io

-10mA

 

10mA

±30

Accuracy @ Ip=± 40A XG

-60mA

 

-60mA

±30

Operating temperature TA

-40

 

105

 

Zero temperature drift Toff

 

0Ma/K

 

 

Gain temperature drift Tgain

-50ppm/K

 

50ppm/K

±30

Output noise

-10mA

 

-10mA

 


CAN Data Format

Message     Description

CAN ID

Data   length

Message     launch type

Signal                    description

Signal                       name

Start bit

Length

Return       Current IP     (mA)

0X3C2

8 bytes

Cyclic transmitted message 10ms cycle

IP Value: 80000000H=0mA 7FFFFFFFH=-1mA 80000001H=1mA

IP-VALUE

24

32

Error indication                0 = Normal 1 = Failure

ERROR INDICATION

32

1

Error Information

CSM_FAIL

33

7

NAME

PRODUCT_NAME

48

16

CRC-8                        POLY: 8+X2+X+1

CRC_8

56

8


Error information

Error description

IP VALUE

ERROR INDICATION

ERROR INFORMATION

Invalidation error

FFFFF FFFH

1

40H

Current exceeds 600A

FFFFF FFFH

1

41H

Overfrequency oscillation exceeding 10ms(>2.5kHz)

FFFFF FFFH

1

44H

The magnetic ring does not oscillate more than 20ms

FFFFF FFFH

1

46H

Entering Failure Mode

FFFFF FFFH

1

47H

No signal exceeding 100ms

FFFFF FFFH

1

49H

Overvoltage(>32V)

FFFFF FFFH

1

4AH














CAN electrical parameters

● CAN2.0

● CAN oscillator tolerance: 0.27%

● Baud rate: 250kpbs

● External resistance: 120Ω

● Data pattern: big-endian


Mechanical characteristics

● General tolerance: ± 0.5 mm

● Other tolerance execution: GB/T 1804-2000-m

● Fixing hole size: Disc installation φ 6.5mm

● Fasten screw: M6

● Recommended fastening torque: 1.8Nm(± 10 %)

● Connector: Tyco AMP 1473672

● Shell material: PBT GF30

● Weight: 80g

● Pin material: tinned brass

● IP GRADE: IP56


Performance parameter definition

● Static output voltage (VQVO): Sensor output voltage in the absence of obvious magnetic field B=0G state

  -BR: The static voltage output VQVO has a constant ratio to the power supply voltage Vcc; VQVO= Vcc/

● Sens (sensitivity): Sens is the slope of the reference output line VOUT=VCC/2+2×IP/IP_MAX, which refers to the change in output as the current changes. Its relationship with the current is : Sens=2/IP_MAX


● Zero temperature drift (Off set with Temperature): Due to the tolerances of internal components, stress and heat dissipation factors, the zero point may shift under stable working conditions


● Sensitivity temperature drift (Sensitivity with Temperature): Due to the influence of the internal temperature compensation coefficient, the sensitivity will change over the entire operating temperature compared to the expected value at room temperature


● Zero point electrical offset voltage ( Electrical offset Voltage): The error caused by the noise of HALL components and the amplification factor of the internal operational amplifier itself is called offset voltage


● Response time : The response time of a sensor refers to the time interval between the final 90% of the applied current and the corresponding value of the sensor output to the applied current.



● Zero magnetic offset voltage ( Magnetic Offset): When the primary current reaches its maximum value of IP→0, the error generated at the output end due to the hysteresis phenomenon of the magnetic core material of the sensor is called the zero magnetic offset voltage.



NOTE

● Incorrect wiring may cause damage to the sensor. After the sensor is connected to a 5V power supply, the measured current passes through the direction of the sensor arrow, and the corresponding voltage value can be measured at the output end.

● -BR mode: Zero point output voltage VQVO=VCC/2, Gain fixed at 2V, The output curve is :VOUT=VCC/2+2×IP/IP_MAX;

If the power supply voltage changes within a certain range, it will cause a change in VOUT;

For example, VCC range 4.75V~5.25V, the static output voltage VCC corresponding to 0A has an output range of 2.375V~2.625V, and the gain does not change with VCC, fixed at 2V. Therefore, the output range of full scale VOUT(IPMAX) is 4.375V~4.625V.

-BF mode: Between VCC= 4.75V ~ 5.25V, the zero output voltage is fixed at 2.5V and the fixed gain is 2V. The output curve is: VOUT=2.5+2×IP/IP_MAX.

Home> Products> Current Sensor> Battery aging cabinet fluxgate current sensor DXE-CAB500
  • Mobile:

    +8618668863822

  • Email:

    cb_dennis@163.com

  • Address:

    Shanghai, Shanghai China

  • Follow us:

NEWSLETTER

Sign up for industry alerts, our latest news. thoughts, and insights from Shanghai Zhilong Electronic Technology Co.,Ltd.

Copyright © 2024 Shanghai Zhilong Electronic Technology Co.,Ltd All rights reserved. Privacy Policy
Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send