Type A+6mA (DC) board mounted Residual Current Protection Module DXE-L1
Product Introduction
● Dedicated to charging piles
● Switching output
● Strong anti-interference ability
● Measure DC6mA & AC30mA
● Fluxgate principle
● High resolution
Standard adaptation
● GB/T 41589—2022/IEC 62752:2018. MOD
● GB/T 40820—2021/IEC 62955:2018
● GB/T 18487.1-2023
Electrical data
Parameter | Minimum | Standard | Maximum | Unit |
Operating Voltage | 4.85 | 5 | 5.15 | V |
Power consumption | 30 | - | 110 | mW |
Voltage input/output, low level | 0 | - | 0.6 | VDC |
Voltage input/output, high level | 4.2 | - | 5 | VDC |
Pressure resistant | 2.5KV,50Hz,1min | |||
Creepage distance | - | 6 | - | mm |
Maximum overcurrent | - | 20 | - | A(rms) |
Weight | - | 10 | - | g |
Power on time | - | 60 | - | ms |
Operating temperature | -40 | 25 | 85 | ℃ |
Storage temperature | -40 | 25 | 85 | ℃ |
Working humidity | 0 | - | 95 | % |
Residual current related characteristic parameters - operating current
Waveform | Frequency | Minimum | Standard | Maximum | Unit |
AC | 50Hz | 20.0 | 22.8 | 26.0 | mA |
A0 | 50Hz | 11.0 | 15.0 | 30.0 | mA |
A90 | 50Hz | 10.0 | 18.0 | 30.0 | mA |
A135 | 50Hz | 10.0 | 24.0 | 35.0 | mA |
2PDC | 50Hz | 3.5 | 5.0 | 7.0 | mA |
3PDC | 50Hz | 3.1 | 4.6 | 6.2 | mA |
S-DC | 50Hz | 3.0 | 4.6 | 6.0 | mA |
Residual current related characteristic parameters - action time
Waveform | Frequency | Current value | Typical value | Unit |
AC | 50Hz | 30mA | 120.0 | ms |
AC | 50Hz | 60mA | 120.0 | ms |
AC | 50Hz | 150mA | 40.0 | ms |
AC | 50Hz | 5A~100A | 40.0 | ms |
A0 | 50Hz | 42mA | 120.0 | ms |
A0 | 50Hz | 84mA | 120.0 | ms |
A0 | 50Hz | 350mA | 40.0 | ms |
A0 | 50Hz | 42mA+6mADC | 120.0 | ms |
A0 | 50Hz | 84mA+6mADC | 120.0 | ms |
A0 | 50Hz | 350mA+6mADC | 40.0 | ms |
2PDC/3PDC | 50Hz | 60mA | 300.0 | ms |
2PDC/3PDC | 50Hz | 120mA | 90.0 | ms |
2PDC/3PDC | 50Hz | 300mA | 40.0 | ms |
2PDC/3PDC | 50Hz | 5A~100A | 40.0 | ms |
S-DC | - | 6mA | 300.0 | ms |
S-DC | - | 60mA | 90.0 | ms |
S-DC | - | 300mA | 40.0 | ms |